Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.470
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Cancer Epidemiol Biomarkers Prev ; 33(5): 638-640, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38689574

RESUMO

Novel breast cancer screening methods that detect greater numbers of occult (nonpalpable) tumors have been rapidly incorporated into clinical practice, with the aim of reducing mortality. Yet, tumor detection has never been validated as a proper surrogate outcome measure for breast cancer mortality. Moreover, the detection of greater numbers of occult cancers increases the risk of overdiagnosis, which refers to detection of tumors that pose no threat to life and would never have been detected in the absence of screening. With recent advances in breast cancer therapy, many cancers that were previously curable only if detected as occult tumors with mammography screening are perhaps now curable even when detected as small palpable tumors, thereby giving us an opportunity to deescalate screening and mitigate the risk of overdiagnosis. Thus, a randomized trial comparing screening mammography versus screening clinical breast examination (CBE), with breast cancer mortality as the endpoint, is now warranted. In such a trial, hand-held ultrasound might aid in the interpretation of screening CBE findings. In conclusion, recent improvements in breast cancer therapy provide the justification to assess the deescalation of breast cancer screening. See related article by Farber et al., p. 671.


Assuntos
Neoplasias da Mama , Detecção Precoce de Câncer , Mamografia , Humanos , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/diagnóstico por imagem , Feminino , Detecção Precoce de Câncer/métodos , Mamografia/métodos
2.
Sci Rep ; 14(1): 10714, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730250

RESUMO

A prompt diagnosis of breast cancer in its earliest phases is necessary for effective treatment. While Computer-Aided Diagnosis systems play a crucial role in automated mammography image processing, interpretation, grading, and early detection of breast cancer, existing approaches face limitations in achieving optimal accuracy. This study addresses these limitations by hybridizing the improved quantum-inspired binary Grey Wolf Optimizer with the Support Vector Machines Radial Basis Function Kernel. This hybrid approach aims to enhance the accuracy of breast cancer classification by determining the optimal Support Vector Machine parameters. The motivation for this hybridization lies in the need for improved classification performance compared to existing optimizers such as Particle Swarm Optimization and Genetic Algorithm. Evaluate the efficacy of the proposed IQI-BGWO-SVM approach on the MIAS dataset, considering various metric parameters, including accuracy, sensitivity, and specificity. Furthermore, the application of IQI-BGWO-SVM for feature selection will be explored, and the results will be compared. Experimental findings demonstrate that the suggested IQI-BGWO-SVM technique outperforms state-of-the-art classification methods on the MIAS dataset, with a resulting mean accuracy, sensitivity, and specificity of 99.25%, 98.96%, and 100%, respectively, using a tenfold cross-validation datasets partition.


Assuntos
Algoritmos , Neoplasias da Mama , Máquina de Vetores de Suporte , Humanos , Neoplasias da Mama/diagnóstico , Feminino , Mamografia/métodos , Diagnóstico por Computador/métodos
3.
Sci Rep ; 14(1): 10001, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693256

RESUMO

Interval breast cancers are diagnosed between scheduled screenings and differ in many respects from screening-detected cancers. Studies comparing the survival of patients with interval and screening-detected cancers have reported differing results. The aim of this study was to investigate the radiological and histopathological features and growth rates of screening-detected and interval breast cancers and subsequent survival. This retrospective study included 942 female patients aged 50-69 years with breast cancers treated and followed-up at Kuopio University Hospital between January 2010 and December 2016. The screening-detected and interval cancers were classified as true, minimal-signs, missed, or occult. The radiological features were assessed on mammograms by one of two specialist breast radiologists with over 15 years of experience. A χ2 test was used to examine the association between radiological and pathological variables; an unpaired t test was used to compare the growth rates of missed and minimal-signs cancers; and the Kaplan-Meier estimator was used to examine survival after screening-detected and interval cancers. Sixty occult cancers were excluded, so a total of 882 women (mean age 60.4 ± 5.5 years) were included, in whom 581 had screening-detected cancers and 301 interval cancers. Disease-specific survival, overall survival and disease-free survival were all worse after interval cancer than after screening-detected cancer (p < 0.001), with a mean follow-up period of 8.2 years. There were no statistically significant differences in survival between the subgroups of screening-detected or interval cancers. Missed interval cancers had faster growth rates (0.47% ± 0.77%/day) than missed screening-detected cancers (0.21% ± 0.11%/day). Most cancers (77.2%) occurred in low-density breasts (< 25%). The most common lesion types were masses (73.9%) and calcifications (13.4%), whereas distortions (1.8%) and asymmetries (1.7%) were the least common. Survival was worse after interval cancers than after screening-detected cancers, attributed to their more-aggressive histopathological characteristics, more nodal and distant metastases, and faster growth rates.


Assuntos
Neoplasias da Mama , Detecção Precoce de Câncer , Mamografia , Humanos , Feminino , Neoplasias da Mama/mortalidade , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Pessoa de Meia-Idade , Idoso , Mamografia/métodos , Detecção Precoce de Câncer/métodos , Finlândia/epidemiologia , Estudos Retrospectivos , Programas de Rastreamento/métodos , Intervalo Livre de Doença
5.
Biomed Phys Eng Express ; 10(3)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38599202

RESUMO

A lot of underdeveloped nations particularly in Africa struggle with cancer-related, deadly diseases. Particularly in women, the incidence of breast cancer is rising daily because of ignorance and delayed diagnosis. Only by correctly identifying and diagnosing cancer in its very early stages of development can be effectively treated. The classification of cancer can be accelerated and automated with the aid of computer-aided diagnosis and medical image analysis techniques. This research provides the use of transfer learning from a Residual Network 18 (ResNet18) and Residual Network 34 (ResNet34) architectures to detect breast cancer. The study examined how breast cancer can be identified in breast mammography pictures using transfer learning from ResNet18 and ResNet34, and developed a demo app for radiologists using the trained models with the best validation accuracy. 1, 200 datasets of breast x-ray mammography images from the National Radiological Society's (NRS) archives were employed in the study. The dataset was categorised as implant cancer negative, implant cancer positive, cancer negative and cancer positive in order to increase the consistency of x-ray mammography images classification and produce better features. For the multi-class classification of the images, the study gave an average accuracy for binary classification of benign or malignant cancer cases of 86.7% validation accuracy for ResNet34 and 92% validation accuracy for ResNet18. A prototype web application showcasing ResNet18 performance has been created. The acquired results show how transfer learning can improve the accuracy of breast cancer detection, providing invaluable assistance to medical professionals, particularly in an African scenario.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Mamografia/métodos , Mama/diagnóstico por imagem , Diagnóstico por Computador , Aprendizado de Máquina
6.
Eur Radiol Exp ; 8(1): 49, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38622388

RESUMO

BACKGROUND: Automatic exposure control (AEC) plays a crucial role in mammography by determining the exposure conditions needed to achieve specific image quality based on the absorption characteristics of compressed breasts. This study aimed to characterize the behavior of AEC for digital mammography (DM), digital breast tomosynthesis (DBT), and low-energy (LE) and high-energy (HE) acquisitions used in contrast-enhanced mammography (CEM) for three mammography systems from two manufacturers. METHODS: Using phantoms simulating various breast thicknesses, 363 studies were acquired using all available AEC modes 165 DM, 132 DBT, and 66 LE-CEM and HE-CEM. AEC behaviors were compared across systems and modalities to assess the impact of different technical components and manufacturers' strategies on the resulting mean glandular doses (MGDs) and image quality metrics such as contrast-to-noise ratio (CNR). RESULTS: For all systems and modalities, AEC increased MGD for increasing phantom thicknesses and decreased CNR. The median MGD values (interquartile ranges) were 1.135 mGy (0.772-1.668) for DM, 1.257 mGy (0.971-1.863) for DBT, 1.280 mGy (0.937-1.878) for LE-CEM, and 0.630 mGy (0.397-0.713) for HE-CEM. Medians CNRs were 14.2 (7.8-20.2) for DM, 4.91 (2.58-7.20) for a single projection in DBT, 11.9 (8.0-18.2) for LE-CEM, and 5.2 (3.6-9.2) for HE-CEM. AECs showed high repeatability, with variations lower than 5% for all modes in DM, DBT, and CEM. CONCLUSIONS: The study revealed substantial differences in AEC behavior between systems, modalities, and AEC modes, influenced by technical components and manufacturers' strategies, with potential implications in radiation dose and image quality in clinical settings. RELEVANCE STATEMENT: The study emphasized the central role of automatic exposure control in DM, DBT, and CEM acquisitions and the great variability in dose and image quality among manufacturers and between modalities. Caution is needed when generalizing conclusions about differences across mammography modalities. KEY POINTS: • AEC plays a crucial role in DM, DBT, and CEM. • AEC determines the "optimal" exposure conditions needed to achieve specific image quality. • The study revealed substantial differences in AEC behavior, influenced by differences in technical components and strategies.


Assuntos
Mamografia , Intensificação de Imagem Radiográfica , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Mamografia/métodos , Imagens de Fantasmas
7.
Pan Afr Med J ; 47: 42, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38681097

RESUMO

Introduction: above the age of 40, women are advised to begin breast examinations and screenings for early detection of breast cancer. The average glandular dose (AGD) provides dosimetric information about the quantity of radiation received by the mammary glands during mammographic exposures. There is, therefore, the need to analyse the radiation dose received by patients presenting for mammography examinations. Methods: a retrospective cross-sectional design was carried out on the data of 663 participants, conveniently sampled between the months of July 2021 and June 2022. Paired T-test was used to compare imaging parameters for cranio-caudal (CC), medio-lateral (ML), automatic exposure control (AEC), manual exposure control (MEC), and left and right breast. Pearson´s correlation was used to test for relationship between imaging parameters and AGD. Results: the mean AGD per exposure was 1.9 ± 0.7 mGy for CC projections and 2.3 ± 1.2 mGy for ML projections. The mean AGD per examination for the study was 4.1 ± 1.4 mGy. A positive correlation was found between AGD per examination and exposure factors (tube loading and tube voltage), compressed breast thickness, and compression force. Patient age had no statistically significant relationship with the AGD per examination. Conclusion: average glandular dose (AGD) was consistent with other findings in literature studies. It was also observed that MEC yielded lower AGD per exposure values than AEC. There was no significant difference in the mean AGD per exposure for left and right breasts.


Assuntos
Neoplasias da Mama , Hospitais de Ensino , Mamografia , Doses de Radiação , Humanos , Gana , Feminino , Mamografia/métodos , Estudos Transversais , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Idoso , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos
8.
Medicina (Kaunas) ; 60(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38674216

RESUMO

Breast cancer remains a significant contributor to morbidity and mortality within oncology. Risk factors, encompassing genetic and environmental influences, significantly contribute to its prevalence. While germline mutations, notably within the BRCA genes, are commonly associated with heightened breast cancer risk, a spectrum of other variants exists among affected individuals. Diagnosis relies on imaging techniques, biopsies, biomarkers, and genetic testing, facilitating personalised risk assessment through specific scoring systems. Breast cancer screening programs employing mammography and other imaging modalities play a crucial role in early detection and management, leading to improved outcomes for affected individuals. Regular screening enables the identification of suspicious lesions or abnormalities at earlier stages, facilitating timely intervention and potentially reducing mortality rates associated with breast cancer. Genetic mutations guide screening protocols, prophylactic interventions, treatment modalities, and patient prognosis. Prophylactic measures encompass a range of interventions, including chemoprevention, hormonal inhibition, oophorectomy, and mastectomy. Despite their efficacy in mitigating breast cancer incidence, these interventions carry potential side effects and psychological implications, necessitating comprehensive counselling tailored to individual cases.


Assuntos
Neoplasias da Mama , Detecção Precoce de Câncer , Mastectomia Profilática , Humanos , Feminino , Neoplasias da Mama/prevenção & controle , Neoplasias da Mama/diagnóstico , Romênia/epidemiologia , Detecção Precoce de Câncer/métodos , Mastectomia Profilática/métodos , Mamografia/métodos , Fatores de Risco
9.
J Cancer Res Ther ; 20(2): 625-632, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38687933

RESUMO

OBJECTIVE: To establish a multimodal model for distinguishing benign and malignant breast lesions. MATERIALS AND METHODS: Clinical data, mammography, and MRI images (including T2WI, diffusion-weighted images (DWI), apparent diffusion coefficient (ADC), and DCE-MRI images) of 132 benign and breast cancer patients were analyzed retrospectively. The region of interest (ROI) in each image was marked and segmented using MATLAB software. The mammography, T2WI, DWI, ADC, and DCE-MRI models based on the ResNet34 network were trained. Using an integrated learning method, the five models were used as a basic model, and voting methods were used to construct a multimodal model. The dataset was divided into a training set and a prediction set. The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of the model were calculated. The diagnostic efficacy of each model was analyzed using a receiver operating characteristic curve (ROC) and an area under the curve (AUC). The diagnostic value was determined by the DeLong test with statistically significant differences set at P < 0.05. RESULTS: We evaluated the ability of the model to classify benign and malignant tumors using the test set. The AUC values of the multimodal model, mammography model, T2WI model, DWI model, ADC model and DCE-MRI model were 0.943, 0.645, 0.595, 0.905, 0.900, and 0.865, respectively. The diagnostic ability of the multimodal model was significantly higher compared with that of the mammography and T2WI models. However, compared with the DWI, ADC, and DCE-MRI models, there was no significant difference in the diagnostic ability of these models. CONCLUSION: Our deep learning model based on multimodal image training has practical value for the diagnosis of benign and malignant breast lesions.


Assuntos
Neoplasias da Mama , Aprendizado Profundo , Mamografia , Imagem Multimodal , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Feminino , Diagnóstico Diferencial , Pessoa de Meia-Idade , Mamografia/métodos , Adulto , Estudos Retrospectivos , Imagem Multimodal/métodos , Idoso , Imageamento por Ressonância Magnética/métodos , Curva ROC , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Mama/diagnóstico por imagem , Mama/patologia
10.
J Appl Clin Med Phys ; 25(5): e14360, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38648734

RESUMO

PURPOSE: Breast density is a significant risk factor for breast cancer and can impact the sensitivity of screening mammography. Area-based breast density measurements may not provide an accurate representation of the tissue distribution, therefore volumetric breast density (VBD) measurements are preferred. Dual-energy mammography enables volumetric measurements without additional assumptions about breast shape. In this work we evaluated the performance of a dual-energy decomposition technique for determining VBD by applying it to virtual anthropomorphic phantoms. METHODS: The dual-energy decomposition formalism was used to quantify VBD on simulated dual-energy images of anthropomorphic virtual phantoms with known tissue distributions. We simulated 150 phantoms with volumes ranging from 50 to 709 mL and VBD ranging from 15% to 60%. Using these results, we validated a correction for the presence of skin and assessed the method's intrinsic bias and variability. As a proof of concept, the method was applied to 14 sets of clinical dual-energy images, and the resulting breast densities were compared to magnetic resonance imaging (MRI) measurements. RESULTS: Virtual phantom VBD measurements exhibited a strong correlation (Pearson's r > 0.95 $r > 0.95$ ) with nominal values. The proposed skin correction eliminated the variability due to breast size and reduced the bias in VBD to a constant value of -2%. Disagreement between clinical VBD measurements using MRI and dual-energy mammography was under 10%, and the difference in the distributions was statistically non-significant. VBD measurements in both modalities had a moderate correlation (Spearman's ρ $\rho \ $ = 0.68). CONCLUSIONS: Our results in virtual phantoms indicate that the material decomposition method can produce accurate VBD measurements if the presence of a third material (skin) is considered. The results from our proof of concept showed agreement between MRI and dual-energy mammography VBD. Assessment of VBD using dual-energy images could provide complementary information in dual-energy mammography and tomosynthesis examinations.


Assuntos
Densidade da Mama , Neoplasias da Mama , Mamografia , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Mamografia/métodos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Imageamento por Ressonância Magnética/métodos
11.
Med Phys ; 51(5): 3322-3333, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38597897

RESUMO

BACKGROUND: The development of a new imaging modality, such as 4D dynamic contrast-enhanced dedicated breast CT (4D DCE-bCT), requires optimization of the acquisition technique, particularly within the 2D contrast-enhanced imaging modality. Given the extensive parameter space, cascade-systems analysis is commonly used for such optimization. PURPOSE: To implement and validate a parallel-cascaded model for bCT, focusing on optimizing and characterizing system performance in the projection domain to enhance the quality of input data for image reconstruction. METHODS: A parallel-cascaded system model of a state-of-the-art bCT system was developed and model predictions of the presampled modulation transfer function (MTF) and the normalized noise power spectrum (NNPS) were compared with empirical data collected in the projection domain. Validation was performed using the default settings of 49 kV with 1.5 mm aluminum filter and at 65 kV and 0.257 mm copper filter. A 10 mm aluminum plate was added to replicate the breast attenuation. Air kerma at the isocenter was measured at different tube current levels. Discrepancies between the measured projection domain metrics and model-predicted values were quantified using percentage error and coefficient of variation (CoV) for MTF and NNPS, respectively. The optimal filtration was for a 5 mm iodine disk detection task at 49, 55, 60, and 65 kV. The detectability index was calculated for the default aluminum filtration and for copper thicknesses ranging from 0.05 to 0.4 mm. RESULTS: At 49 kV, MTF errors were +5.1% and -5.1% at 1 and 2 cycles/mm, respectively; NNPS CoV was 5.3% (min = 3.7%; max = 8.5%). At 65 kV, MTF errors were -0.8% and -3.2%; NNPS CoV was 13.1% (min = 11.4%; max = 16.9%). Air kerma output was linear, with 11.67 µGy/mA (R2 = 0.993) and 19.14 µGy/mA (R2 = 0.996) at 49 and 65 kV, respectively. For iodine detection, a 0.25 mm-thick copper filter at 65 kV was found optimal, outperforming the default technique by 90%. CONCLUSION: The model accurately predicts bCT system performance, specifically in the projection domain, under varied imaging conditions, potentially contributing to the enhancement of 2D contrast-enhanced imaging in 4D DCE-bCT.


Assuntos
Mama , Meios de Contraste , Meios de Contraste/química , Mama/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Imagens de Fantasmas , Humanos , Mamografia/métodos , Mamografia/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído
12.
Radiol Artif Intell ; 6(3): e230375, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38597784

RESUMO

Purpose To explore the stand-alone breast cancer detection performance, at different risk score thresholds, of a commercially available artificial intelligence (AI) system. Materials and Methods This retrospective study included information from 661 695 digital mammographic examinations performed among 242 629 female individuals screened as a part of BreastScreen Norway, 2004-2018. The study sample included 3807 screen-detected cancers and 1110 interval breast cancers. A continuous examination-level risk score by the AI system was used to measure performance as the area under the receiver operating characteristic curve (AUC) with 95% CIs and cancer detection at different AI risk score thresholds. Results The AUC of the AI system was 0.93 (95% CI: 0.92, 0.93) for screen-detected cancers and interval breast cancers combined and 0.97 (95% CI: 0.97, 0.97) for screen-detected cancers. In a setting where 10% of the examinations with the highest AI risk scores were defined as positive and 90% with the lowest scores as negative, 92.0% (3502 of 3807) of the screen-detected cancers and 44.6% (495 of 1110) of the interval breast cancers were identified with AI. In this scenario, 68.5% (10 987 of 16 040) of false-positive screening results (negative recall assessment) were considered negative by AI. When 50% was used as the cutoff, 99.3% (3781 of 3807) of the screen-detected cancers and 85.2% (946 of 1110) of the interval breast cancers were identified as positive by AI, whereas 17.0% (2725 of 16 040) of the false-positive results were considered negative. Conclusion The AI system showed high performance in detecting breast cancers within 2 years of screening mammography and a potential for use to triage low-risk mammograms to reduce radiologist workload. Keywords: Mammography, Breast, Screening, Convolutional Neural Network (CNN), Deep Learning Algorithms Supplemental material is available for this article. © RSNA, 2024 See also commentary by Bahl and Do in this issue.


Assuntos
Inteligência Artificial , Neoplasias da Mama , Detecção Precoce de Câncer , Mamografia , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/diagnóstico , Feminino , Mamografia/métodos , Noruega/epidemiologia , Estudos Retrospectivos , Pessoa de Meia-Idade , Detecção Precoce de Câncer/métodos , Idoso , Adulto , Programas de Rastreamento/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
13.
Cancer Med ; 13(8): e7128, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38659408

RESUMO

PURPOSE: Contrast-enhanced spectral imaging (CEM) is a new mammography technique, but its diagnostic value in dense breasts is still inconclusive. We did a systematic review and meta-analysis of studies evaluating the diagnostic performance of CEM for suspicious findings in dense breasts. MATERIALS AND METHODS: The PubMed, Embase, and Cochrane Library databases were searched systematically until August 6, 2023. Prospective and retrospective studies were included to evaluate the diagnostic performance of CEM for suspicious findings in dense breasts. The QUADAS-2 tool was used to evaluate the quality and risk of bias of the included studies. STATA V.16.0 and Review Manager V.5.3 were used to meta-analyze the included studies. RESULTS: A total of 10 studies (827 patients, 958 lesions) were included. These 10 studies reported the diagnostic performance of CEM for the workup of suspicious lesions in patients with dense breasts. The summary sensitivity and summary specificity were 0.95 (95% CI, 0.92-0.97) and 0.81 (95% CI, 0.70-0.89), respectively. Enhanced lesions, circumscribed margins, and malignancy were statistically correlated. The relative malignancy OR value of the enhanced lesions was 28.11 (95% CI, 6.84-115.48). The relative malignancy OR value of circumscribed margins was 0.17 (95% CI, 0.07-0.45). CONCLUSION: CEM has high diagnostic performance in the workup of suspicious findings in dense breasts, and when lesions are enhanced and have irregular margins, they are often malignant.


Assuntos
Densidade da Mama , Neoplasias da Mama , Meios de Contraste , Mamografia , Feminino , Humanos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mamografia/métodos , Sensibilidade e Especificidade
14.
Radiology ; 311(1): e232133, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38687216

RESUMO

Background The performance of publicly available large language models (LLMs) remains unclear for complex clinical tasks. Purpose To evaluate the agreement between human readers and LLMs for Breast Imaging Reporting and Data System (BI-RADS) categories assigned based on breast imaging reports written in three languages and to assess the impact of discordant category assignments on clinical management. Materials and Methods This retrospective study included reports for women who underwent MRI, mammography, and/or US for breast cancer screening or diagnostic purposes at three referral centers. Reports with findings categorized as BI-RADS 1-5 and written in Italian, English, or Dutch were collected between January 2000 and October 2023. Board-certified breast radiologists and the LLMs GPT-3.5 and GPT-4 (OpenAI) and Bard, now called Gemini (Google), assigned BI-RADS categories using only the findings described by the original radiologists. Agreement between human readers and LLMs for BI-RADS categories was assessed using the Gwet agreement coefficient (AC1 value). Frequencies were calculated for changes in BI-RADS category assignments that would affect clinical management (ie, BI-RADS 0 vs BI-RADS 1 or 2 vs BI-RADS 3 vs BI-RADS 4 or 5) and compared using the McNemar test. Results Across 2400 reports, agreement between the original and reviewing radiologists was almost perfect (AC1 = 0.91), while agreement between the original radiologists and GPT-4, GPT-3.5, and Bard was moderate (AC1 = 0.52, 0.48, and 0.42, respectively). Across human readers and LLMs, differences were observed in the frequency of BI-RADS category upgrades or downgrades that would result in changed clinical management (118 of 2400 [4.9%] for human readers, 611 of 2400 [25.5%] for Bard, 573 of 2400 [23.9%] for GPT-3.5, and 435 of 2400 [18.1%] for GPT-4; P < .001) and that would negatively impact clinical management (37 of 2400 [1.5%] for human readers, 435 of 2400 [18.1%] for Bard, 344 of 2400 [14.3%] for GPT-3.5, and 255 of 2400 [10.6%] for GPT-4; P < .001). Conclusion LLMs achieved moderate agreement with human reader-assigned BI-RADS categories across reports written in three languages but also yielded a high percentage of discordant BI-RADS categories that would negatively impact clinical management. © RSNA, 2024 Supplemental material is available for this article.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Estudos Retrospectivos , Neoplasias da Mama/diagnóstico por imagem , Pessoa de Meia-Idade , Sistemas de Informação em Radiologia/estatística & dados numéricos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Mama/diagnóstico por imagem , Idoso , Adulto , Idioma , Ultrassonografia Mamária/métodos
15.
Radiology ; 311(1): e231991, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38687218

RESUMO

Background Digital breast tomosynthesis (DBT) is often inadequate for screening women with a personal history of breast cancer (PHBC). The ongoing prospective Tomosynthesis or Contrast-Enhanced Mammography, or TOCEM, trial includes three annual screenings with both DBT and contrast-enhanced mammography (CEM). Purpose To perform interim assessment of cancer yield, stage, and recall rate when CEM is added to DBT in women with PHBC. Materials and Methods From October 2019 to December 2022, two radiologists interpreted both examinations: Observer 1 reviewed DBT first and then CEM, and observer 2 reviewed CEM first and then DBT. Effects of adding CEM to DBT on incremental cancer detection rate (ICDR), cancer type and node status, recall rate, and other performance characteristics of the primary radiologist decisions were assessed. Results Among the participants (mean age at entry, 63.6 years ± 9.6 [SD]), 1273, 819, and 227 women with PHBC completed year 1, 2, and 3 screening, respectively. For observer 1, year 1 cancer yield was 20 of 1273 (15.7 per 1000 screenings) for DBT and 29 of 1273 (22.8 per 1000 screenings; ICDR, 7.1 per 1000 screenings [95% CI: 3.2, 13.4]) for DBT plus CEM (P < .001). Year 2 plus 3 cancer yield was four of 1046 (3.8 per 1000 screenings) for DBT and eight of 1046 (7.6 per 1000 screenings; ICDR, 3.8 per 1000 screenings [95% CI: 1.0, 7.6]) for DBT plus CEM (P = .001). Year 1 recall rate for observer 1 was 103 of 1273 (8.1%) for (incidence) DBT alone and 187 of 1273 (14.7%) for DBT plus CEM (difference = 84 of 1273, 6.6% [95% CI: 5.3, 8.1]; P < .001). Year 2 plus 3 recall rate was 40 of 1046 (3.8%) for DBT and 92 of 1046 (8.8%) for DBT plus CEM (difference = 52 of 1046, 5.0% [95% CI: 3.7, 6.3]; P < .001). In 18 breasts with cancer detected only at CEM after integration of both observers, 13 (72%) cancers were invasive (median tumor size, 0.6 cm) and eight of nine (88%) with staging were N0. Among 1883 screenings with adequate reference standard, there were three interval cancers (one at the scar, two in axillae). Conclusion CEM added to DBT increased early breast cancer detection each year in women with PHBC, with an accompanying approximately 5.0%-6.6% recall rate increase. Clinical trial registration no. NCT04085510 © RSNA, 2024 Supplemental material is available for this article.


Assuntos
Neoplasias da Mama , Meios de Contraste , Mamografia , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Estudos Prospectivos , Pessoa de Meia-Idade , Detecção Precoce de Câncer/métodos , Idoso , Intensificação de Imagem Radiográfica/métodos , Mama/diagnóstico por imagem
16.
Clin Imaging ; 109: 110129, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38582071

RESUMO

PURPOSE: Breast arterial calcifications (BAC) are incidentally observed on mammograms, yet their implications remain unclear. We investigated lifestyle, reproductive, and cardiovascular determinants of BAC in women undergoing mammography screening. Further, we investigated the relationship between BAC, coronary arterial calcifications (CAC) and estimated 10-year atherosclerotic cardiovascular (ASCVD) risk. METHODS: In this cross-sectional study, we obtained reproductive history and CVD risk factors from 215 women aged 18 or older who underwent mammography and cardiac computed tomographic angiography (CCTA) within a 2-year period between 2007 and 2017 at hospital. BAC was categorized as binary (present/absent) and semi-quantitatively (mild, moderate, severe). CAC was determined using the Agatston method and recorded as binary (present/absent). Adjusted odds ratios (ORs) and 95 % confidence intervals (CIs) were calculated, accounting for age as a confounding factor. ASCVD risk over a 10-year period was calculated using the Pooled Cohort Risk Equations. RESULTS: Older age, systolic and diastolic blood pressures, higher parity, and younger age at first birth (≤28 years) were significantly associated with greater odds of BAC. Women with both BAC and CAC had the highest estimated 10-year risk of ASCVD (13.30 %). Those with only BAC (8.80 %), only CAC (5.80 %), and no BAC or CAC (4.40 %) had lower estimated 10-year risks of ASCVD. No association was detected between presence of BAC and CAC. CONCLUSIONS: These findings support the hypothesis that BAC on a screening mammogram may help to identify women at potentially increased risk of future cardiovascular disease without additional cost and radiation exposure.


Assuntos
Doenças Mamárias , Calcinose , Doenças Cardiovasculares , Doença da Artéria Coronariana , Calcificação Vascular , Feminino , Humanos , Mama/diagnóstico por imagem , Estudos Transversais , Mamografia/métodos , Doenças Mamárias/diagnóstico por imagem , Fatores de Risco , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/complicações , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/epidemiologia
17.
J Int Med Res ; 52(4): 3000605241237867, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38663911

RESUMO

Breast cancer (BC) is the most prominent form of cancer among females all over the world. The current methods of BC detection include X-ray mammography, ultrasound, computed tomography, magnetic resonance imaging, positron emission tomography and breast thermographic techniques. More recently, machine learning (ML) tools have been increasingly employed in diagnostic medicine for its high efficiency in detection and intervention. The subsequent imaging features and mathematical analyses can then be used to generate ML models, which stratify, differentiate and detect benign and malignant breast lesions. Given its marked advantages, radiomics is a frequently used tool in recent research and clinics. Artificial neural networks and deep learning (DL) are novel forms of ML that evaluate data using computer simulation of the human brain. DL directly processes unstructured information, such as images, sounds and language, and performs precise clinical image stratification, medical record analyses and tumour diagnosis. Herein, this review thoroughly summarizes prior investigations on the application of medical images for the detection and intervention of BC using radiomics, namely DL and ML. The aim was to provide guidance to scientists regarding the use of artificial intelligence and ML in research and the clinic.


Assuntos
Neoplasias da Mama , Aprendizado de Máquina , Humanos , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/diagnóstico por imagem , Feminino , Redes Neurais de Computação , Mamografia/métodos , Aprendizado Profundo , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos
18.
Breast Cancer Res ; 26(1): 68, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649889

RESUMO

BACKGROUND: Artificial intelligence (AI) algorithms for the independent assessment of screening mammograms have not been well established in a large screening cohort of Asian women. We compared the performance of screening digital mammography considering breast density, between radiologists and AI standalone detection among Korean women. METHODS: We retrospectively included 89,855 Korean women who underwent their initial screening digital mammography from 2009 to 2020. Breast cancer within 12 months of the screening mammography was the reference standard, according to the National Cancer Registry. Lunit software was used to determine the probability of malignancy scores, with a cutoff of 10% for breast cancer detection. The AI's performance was compared with that of the final Breast Imaging Reporting and Data System category, as recorded by breast radiologists. Breast density was classified into four categories (A-D) based on the radiologist and AI-based assessments. The performance metrics (cancer detection rate [CDR], sensitivity, specificity, positive predictive value [PPV], recall rate, and area under the receiver operating characteristic curve [AUC]) were compared across breast density categories. RESULTS: Mean participant age was 43.5 ± 8.7 years; 143 breast cancer cases were identified within 12 months. The CDRs (1.1/1000 examination) and sensitivity values showed no significant differences between radiologist and AI-based results (69.9% [95% confidence interval [CI], 61.7-77.3] vs. 67.1% [95% CI, 58.8-74.8]). However, the AI algorithm showed better specificity (93.0% [95% CI, 92.9-93.2] vs. 77.6% [95% CI, 61.7-77.9]), PPV (1.5% [95% CI, 1.2-1.9] vs. 0.5% [95% CI, 0.4-0.6]), recall rate (7.1% [95% CI, 6.9-7.2] vs. 22.5% [95% CI, 22.2-22.7]), and AUC values (0.8 [95% CI, 0.76-0.84] vs. 0.74 [95% CI, 0.7-0.78]) (all P < 0.05). Radiologist and AI-based results showed the best performance in the non-dense category; the CDR and sensitivity were higher for radiologists in the heterogeneously dense category (P = 0.059). However, the specificity, PPV, and recall rate consistently favored AI-based results across all categories, including the extremely dense category. CONCLUSIONS: AI-based software showed slightly lower sensitivity, although the difference was not statistically significant. However, it outperformed radiologists in recall rate, specificity, PPV, and AUC, with disparities most prominent in extremely dense breast tissue.


Assuntos
Inteligência Artificial , Densidade da Mama , Neoplasias da Mama , Detecção Precoce de Câncer , Mamografia , Radiologistas , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Neoplasias da Mama/epidemiologia , Mamografia/métodos , Adulto , Pessoa de Meia-Idade , Detecção Precoce de Câncer/métodos , Estudos Retrospectivos , República da Coreia/epidemiologia , Curva ROC , Mama/diagnóstico por imagem , Mama/patologia , Algoritmos , Programas de Rastreamento/métodos , Sensibilidade e Especificidade
19.
Eur Radiol Exp ; 8(1): 32, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556593

RESUMO

BACKGROUND: Contrast-enhanced mammography (CEM) is a promising technique. We evaluated the diagnostic potential of CEM performed immediately after contrast-enhanced computed tomography (CE-CT). METHODS: Fifty patients with breast cancer underwent first CE-CT and then CEM without additional contrast material injection. Two independent radiologists evaluated CEM images. The sensitivity of CEM for detecting index and additional malignant lesions was compared with that of mammography/ultrasonography by the McNemar test, using histopathology as a reference standard. Interobserver agreement for detection of malignant lesions, for classifying index tumors, and for evaluating index tumor size and extent was assessed using Cohen κ. Pearson correlation was used for correlating index tumor size/extent at CEM or mammography/ultrasonography with histopathology. RESULTS: Of the 50 patients, 30 (60%) had unifocal disease while 20 (40%) had multicentric or multifocal disease; 5 of 20 patients with multicentric disease (25%) had bilateral involvement, for a total of 78 malignant lesions, including 72 (92%) invasive ductal and 6 (8%) invasive lobular carcinomas. Sensitivity was 63/78 (81%, 95% confidence interval 70.27-88.82) for unenhanced breast imaging and 78/78 (100%, 95.38-100) for CEM (p < 0.001). The interobserver agreement for overall detection of malignant lesions, for classifying index tumor, and for evaluating index tumor size/extent were 0.94, 0.95, and 0.86 κ, respectively. For index tumor size/extent, correlation coefficients as compared with histological specimens were 0.50 for mammography/ultrasonography and 0.75 for CEM (p ≤ 0.010). CONCLUSIONS: CEM acquired immediately after CE-CT without injection of additional contrast material showed a good performance for local staging of breast cancer. RELEVANCE STATEMENT: When the CEM suite is near to the CE-CT acquisition room, CEM acquired immediately after, without injection of additional contrast material, could represent a way for local staging of breast cancer to be explored in larger prospective studies. KEY POINTS: • CEM represents a new accurate tool in the field of breast imaging. • An intravenous injection of iodine-based contrast material is required for breast gland evaluation. • CEM after CE-CT could provide a one-stop tool for breast cancer staging.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Meios de Contraste , Estudos Prospectivos , Mamografia/métodos , Tomografia Computadorizada por Raios X/métodos
20.
Comput Methods Programs Biomed ; 248: 108117, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38498955

RESUMO

This project addresses the global challenge of breast cancer, particularly in low-resource settings, by creating a pioneering mammography database. Breast cancer, identified by the World Health Organization as a leading cause of cancer death among women, often faces diagnostic and treatment resource constraints in low- and middle-income countries. To enhance early diagnosis and address educational setbacks, the project focuses on leveraging artificial intelligence (AI) technologies through a comprehensive database. Developed in collaboration with Ambra Health, a cloud-based medical image management software, the database comprises 941 mammography images from 100 anonymized cases, with 62 % including 3D images. Accessible through http://mamografia.unifesp.br, the platform facilitates a simple registration process and an advanced search system based on 169 clinical and imaging variables. The website, customizable to the user's native language, ensures data security through an automatic anonymization system. By providing high-resolution, 3D digital images and supplementary clinical information, the platform aims to promote education and research in breast cancer diagnosis, representing a significant advancement in resource-constrained healthcare environments.


Assuntos
Inteligência Artificial , Neoplasias da Mama , Feminino , Humanos , Medicina de Precisão , Mamografia/métodos , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA